Description
Performs comprehensive monitoring of four critical systems in one compact organic LED digital monitor
DC System Monitoring (up to two batteries)
One input monitors the DC voltage, state-of-charge, current for one battery bank and another input monitors the voltage of an additional battery bank. Alarms include high and low voltage, high current, and low battery.
AC System Monitoring
The VSM monitors a single AC voltage, current, and frequency. Alarms include high and low voltage, high current, and high and low frequency.
Bilge & Tank Monitoring
The M2 VSM has two inputs that can be configured as a bilge or tank monitor.
When configured as a bilge input, monitoring functions include pump active, cycle count in the last 24-hours, average cycles in a typical 24-hour period, and total cycles.
High alarms can be set for both the minutes of run time in the last hour as well as the number or cycle counts in the last 24-hours.
When configured as a tank input, tank status can be represented in both capacity (gallons or litres) or as a percentage of capacity. Custom tank shapes can be auto-calibrated or programmed. Both high and low level alarms can be set for all tanks.
Regulatory
Monitor face is IP66 – protected against powerful water jets, when installed according to instructions (see inside back cover).
DC Specifications
Nominal System Voltage: 12V, 24V, 36V, 48V
Operating Voltage: 7-70V
Minimum Current Draw: 15mA @ 12V, display off, 8mA @ 24V, display off
Voltage Accuracy: +/- 1%
Current Range: -500A to 500A
Current Accuracy: +/- 1%
AC Specifications:
Nominal System Voltage: 230V @ 50Hz, (Europe)
Operating Voltage: 40-300V
Voltage Accuracy (RMS): +/- 1%
Current Range: 0-150A
Current Accuracy (RMS): +/- 2%
Frequency: 40-90Hz
Tank Senders Supported:
10-180 ? VDO, 240-33 ? Teleflex
Blue Sea Systems Ultrasonic Tank Senders (sold separately)
Weight – 0
SKU – 8-21850
Product Type – Electrical & Navigation > Meters & Monitoring > DC